Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 8 Of 12 >> CEM-6D07: Relay, Window Lift RR Up. Signal Too High. Permanent Fault (1999-2004) >> Signal too high. Permanent fault >> Checking the control unit

Checking the control unit

Remove window lift relay 2/117 from CEM socket.

Check the relay coil driver circuit for a short circuit to voltage supply by checking the voltage between #2 and ground in the relay socket to relay 2/117.

For additional information regarding short circuits to voltage supply, see Short-circuit to supply voltage. Permanent faults .

HINT: The voltage between #2 and ground should be approximately 0 volt. If the voltmeter indicates an incorrect value, the control unit must be replaced. 

Additional information 

Fig 1: Identifying Voltage Display
GLL101041Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relays
GLL104067Courtesy of VOLVO CARS OF NORTH AMERICA.