Checking cable
Check the supply voltage to the keypad unit/carphone module by measuring between #C5 and #C2 on the keypad unit/carphone module connector.
Check the supply voltage from the keypad unit/carphone module to the carphone box by measuring between #B5 and #B2 on the keypad unit/carphone module connector. The fault is in the keypad/carphone module unit if the supply voltage to the carphone box is lower.
Other information:
- To access/replace the carphone box, see Carphone box .
- To access/replace the keypad/carphone module, see Radio/carphone, replacing .
- To connect the breakout box, see Connecting the breakout box, Carphone module .
- For information about signals and connectors, see Signal specification, Keypad unit / carphone module (PHM) .
Continue when the fault has been remedied.
- Continue
Refer to Verification