LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation - Symptom Related Diagnostic Procedures >> Checking The Coolant Level Guard (1999-2004) >> Checking the coolant level guard >> Checking the wires

Checking the wires

Check wire between coolant level guard 1 and engine control unit 8B for a short circuit to voltage supply as described in Short-circuit to supply voltage. Permanent faults , a short circuit to ground as described in Short-circuit to ground, permanent faults and an open circuit as described in Open-circuit, permanent faults .

HINT: The voltage should be 0 V in 1 and 2 with closed coolant level guard (lamp lights) and voltage should be 12 V in 1 with open circuit (lamp off). 

Do the necessary corrective action.

Additional information: 

Fig 1: Identifying Ohms Display
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.