Testing with Volvo Battery Analyzer 3100/3200
Volvo Battery Analyzer 3100/3200 is used to test batteries as follows
Volvo Battery Analyzer 3100/3200 is used to test the battery. The following is a description of how the tool is used and the text shown in the display.
For further instructions, see the separate instruction card supplied with Volvo Battery Analyzer 3100/3200.
Setting the language
Set the language according to the instructions on the separate instruction card. English must be selected for markets where the relevant language cannot be selected for Volvo Battery Analyzer 3100/3200.
The display when testing batteries
Connect the tool cables directly to the battery.
The start window (below) is displayed for 3 seconds:
| - | - | - |
| - | VOLVO 3100/3200 VERSION 1.0 |
- |
| - | - | - |
Scroll to select whether the test will take place inside or outside the vehicle (see the instruction card). Outside the car means that the battery is not connected to the vehicle's electrical system. Then press ENTER (see the instruction card).
| - | - | - |
| - | SELECT TEST ↑↓ IN-VEHICLE ← |
- |
| - | - | - |
| - | - | - |
| - | SELECT TEST ↑↓ OUT-OF-VEHICLE ← |
- |
| - | - | - |
Then select whether the battery to be tested is a genuine Volvo battery or another make.
| - | - | - |
| - | BATTERY TYPE ↑↓ VOLVO BATTERY ← |
- |
| - | - | - |
| - | - | - |
| - | BATTERY TYPE ↑↓ NON-VOLVO ← |
- |
| - | - | - |
Establish the test standard by checking the markings on the battery. CCA/SAE and DIN tests use different standards. Select the test standard. Press ENTER.
| - | - | - |
| - | SELECT MODE ↑↓ BY CCA ← |
- |
| - | - | - |
| - | - | - |
| - | SELECT MODE ↑↓ BY DIN (A) ← |
- |
| - | - | - |
Scroll to the relevant value for the cold cranking amperes (cold cranking amperes according to CCA/SAE or DIN - listed on the battery). Press ENTER:
| - | - | - |
| - | SELECT RATING ↑↓ 500 A ← |
- |
| - | - | - |
| - | - | - |
| - | SELECT RATING ↑↓ 500 CCA ← |
- |
| - | - | - |
The instrument now analyzes the battery and one of the following is displayed:
| - | - | - |
| - | *** TESTING *** 500 A (SAE) |
- |
| - | - | - |
| - | - | - |
| - | *** TESTING *** 500 A (DIN) |
- |
| - | - | - |
When the analysis is complete, the instrument will display one of the following results:
| - | - | - |
| - | xxxx V GOOD BATTERY |
- |
| - | - | - |
| - | - | - |
| - | xxxx V GOOD-RECHARGE |
- |
| - | - | - |
| - | - | - |
| - | xxxx V CHARGE & RETEST |
- |
| - | - | - |
| - | - | - |
| - | xxxx V REPLACE BATTERY |
- |
| - | - |
| - | - | - |
| - | xxxx V BAD CELL-REPLACE |
- |
| - | - | - |
The voltage displayed is an indication of the charge status of the battery.
After displaying the above result, the test instrument will shift between this result and the charge status. The state of charge (%) is displayed in intervals of 25%.
GOOD BATTERY
If GOOD BATTERY is displayed, the following text for the state of charge will be shown:
| - | - | - |
| - | STATE OF CHARGE: 75-100% |
- |
| - | - | - |
GOOD-RECHARGE/CHARGE & RETEST
If GOOD-RECHARGE or CHARGE & RETEST is displayed, one of the following alternatives for the state of charge will be shown in the display:
| - | - | - |
| - | STATE OF CHARGE: 0-25% |
- |
| - | - | - |
| - | - | - |
| - | STATE OF CHARGE: 25-50% |
- |
| - | - | - |
| - | - | - |
| - | STATE OF CHARGE: 50-75% |
- |
| - | - | - |
CHARGE & RETEST means that the battery must be recharged and then tested again. The battery must be discarded if the same result is obtained.
REPLACE BATTERY/BAD CELL-REPLACE
If REPLACE BATTERY or BAD CELL-REPLACE is displayed, the following text for the state of charge will be shown:
| - | - | - |
| - | STATE OF CHARGE: REPLACE BATTERY |
- |
| - | - | - |
REPLACE BATTERY means that the battery must be discarded.