Checking for an open-circuit in the cable
Check the cable between control module terminal #4 and fuse 11/9 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification
Check the cable between ignition switch terminal 15I and fuse 11/9 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification
Check the cable between control module terminal #9 and fuse 11/11 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification
Check the cable between the battery positive terminal and fuse 11/11 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification
Check the cable between control module terminal #25 and fuse 11/12 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification
Check the cable between the battery positive terminal and fuse 11/12 for an open-circuit according to Open-circuit, permanent faults .
- Continue
Refer to Verification