Checking cables and components
Check the cable between the power seat module (PSM) #3D and the Hall sensor, and the cable between the power seat module (PSM) #4D and the Hall sensor for an open-circuit according to Open-circuit, permanent faults , a short-circuit to ground according to Short-circuit to ground, permanent faults and a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .
Check hall sensor and replace if necessary.
HINT: The sensor should generate a pulsed signal.
Remedy as necessary.
Other information
- To connect the breakout box, see Connecting the breakout box, power seat module (PSM) .
- For information on signals, refer to Output signals to the motors .
- Continue
Refer to Verification