Intermittent fault
Check control unit and wire connector (54/3R, 54/10 or 54/11 and 3/126 or 3/127) for Contact resistance and oxidation , and for a loose contact as described in Loose connections (terminals) .
Check that main fuse (11A/2) in engine compartment relay/fuse box is correctly installed.
If control unit is on the left side, check that interior fuse (11C/35) in interior fuse box is correctly installed.
If control unit is on the right side, check that interior fuse (11C/36) in interior fuse box is correctly installed.
Check the wire between control unit 12B and the ignition lock for an intermittent short circuit to ground as described in Short-circuit to ground, intermittent faults , and for an intermittent open circuit as described in Open-circuit, intermittent faults .
Check the wire between control unit 9B and ground: Check front left or right seat support for an intermittent short circuit to ground as described in Short-circuit to ground, intermittent faults , and for an intermittent open circuit as described in Open-circuit, intermittent faults .
Additional information:
- With ignition off, voltage between control unit 12B and ground should be battery voltage.
- To connect the test box, see Connecting breakout box .
- For information on signals and additional values, see Signal specification .
- To access the door control unit, see Driver's door module/passenger door module (DDM/PDM), replacing .
- Continue
Refer to Fault-tracing information