Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Media, Communication And Navigation - Specifications, Electrical/Electronic >> Description Of Parameters. PHM (2001-2004) >> Description of parameters >> Parameters, status >> Status, alarm (Volvo On Call/Volvo On Call Plus)

Status, alarm (Volvo On Call/Volvo On Call Plus)

This parameter indicates how the phone module (PHM) sees the status of the alarm.

This parameter is used by phone modules (PHM) with Volvo On Call/Volvo On Call Plus functionality. If the car alarm is triggered, for example during a theft attempt, information about the status of the alarm from the upper electronic module (UEM) to the phone module (PHM) via the central electronic module (CEM). The phone module (PHM) then transmits vehicle data to the Volvo On Call/Volvo On Call Plus Service Center which contacts the owner and informs him what has happened.

Alarm status 1 = the alarm has been disarmed with sensors

Alarm status 2 = the alarm has been armed with sensors

Alarm status 3 = the alarm is armed without sensors (reduced alarm)

Alarm status 4 = triggered alarm with sensors

Alarm status 5 = triggered alarm without sensors

Alarm status 6 = the alarm has been disarmed with sensors