Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Gauges & Instrument Panels >> Audio Module (AUM) & Phone Module (PHM) Diagnostic Trouble Codes >> PHM-0001: Power Supply. Faulty Signal. Permanent Fault (USA/CDN) (2001-2004) >> Faulty signal. Permanent fault >> Checking power supply >> Checking power supply

Checking power supply

Measure the power supply to the carphone module between terminal #A6 and the battery positive terminal.

Measure the battery voltage.

If the difference between the carphone supply voltage and battery voltage is less than 2.5 V there is an internal fault in the carphone module. If the difference is greater than 2.5 V the fault is in the supply cable.

Remedy as necessary.

Other information: 

Fig 1: Identifying Breakout Box
GLL100304Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Voltage Display
GLL101041Courtesy of VOLVO CARS OF NORTH AMERICA.

Continue when the fault has been remedied.