Checking the output signal
Activate the horn.
HINT: Listen for a click from the relay to determine whether the fault is in the relay circuit or in the wiring for the horn itself.
- The horn is functioning. Troubleshooting has been completed.
- The relay clicks. Refer to Checking the wiring for the horn .
- The relay does not click. Refer to Checking the cable for the relay .