Connect the test equipment
Courtesy of VOLVO CARS OF NORTH AMERICA.
- Remove the turbocharger (TC) control valve from the air cleaner (ACL) housing
- Remove the yellow marked hose (A) from the turbocharger (TC) control valve
- Connect special tool
9995230
and pressure regulator
9995766
to the removed hose
- Connect the workshop air supply to
9995766
.