Checking the wiring
- Check the VGLA control module connector for Contact resistance and oxidation
.
Check passenger compartment fuse 8. If the fuse is blown, check the circuit after the fuse for a short-circuit to ground according to Short-circuit to ground, permanent faults . For further information about the circuit, see the relevant Wiring Diagram Service Information.
Check the cable between passenger compartment fuse 8 and VGLA control module terminal #A26 (A26) for an open-circuit according to Open-circuit, permanent faults .
Other information:
- To access and replace the control module see VGLA-control module
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) .
- Continue
Refer to Verification
Check the VGLA control module connector for Contact resistance and oxidation .
Check the cable between VGLA control module terminal #A12 (A12) and passenger compartment fusebox terminal #G19 for an open-circuit according to Open-circuit, permanent faults .
Other information:
- To access and replace the control module see VGLA-control module
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) .
- Continue
Refer to Verification
Check the VGLA control module connector for Contact resistance and oxidation .
Check the cable between VGLA control module terminal #A13 (A13) and passenger compartment fusebox terminal #I21 for an open-circuit according to Open-circuit, permanent faults .
Other information:
- To access and replace the control module, see VGLA-control module
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) .
Select "Continue" when complete.
- Continue
Refer to Verification