Checking wiring and connectors
Check the central locking switch and VGLA control module connectors for Contact resistance and oxidation .
Check the cable between VGLA control module #A4 (A4) and central locking switch #3 and the cable between central locking switch #5 and ground for an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Replacing the component
Check the central locking switch and VGLA control module connectors for Contact resistance and oxidation .
Check the cable between central locking switch #2 and VGLA control module #A6 (A6) for an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Replacing the component