Checking the resistance in the cable
- Ignition off.
- Disconnect the central locking system control module from the connector, Checking the 10-CD changer .CAUTION: Avoid touching the control module terminal pins. There is a risk of static discharge which may damage the control module.
Connect an ohmmeter between SRS control module connector #40 and central locking system connector #A10. Check for an open-circuit according to Open-circuit, permanent faults .
The ohmmeter should read approximately 0 Ω.
- OK
Refer to Check the central locking system cable for a short-circuit to ground
- NOT OK
Refer to Replacing the component