Check the central locking system cable for a short-circuit to ground
- Ignition off.
- Disconnect the battery negative lead.
- Connect the SRS control module connector.
- The connector for the central locking system control module must be disconnected.
Connect an ohmmeter between ground and central locking system connector #10A.
The ohmmeter should read approximately 1.2 MΩ.