Checking cables
Check the cable between overload relay 2/30 terminal 3 and the RTI control module #B2 for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .
NOTE:
Check the other cables in the relay circuit for a short-circuit to supply voltage Short-circuit to supply voltage. Permanent faults .
Check control cable between overload relay 2/30 terminal 3 and ignition switch for a short-circuit to supply voltage for a short-circuit to supply voltage Short-circuit to supply voltage. Permanent faults .
If no faults are detected in the cables, try a new relay.
Remedy as necessary.
Other information:
- For further information about the circuit after the ignition switch, see the Service Manual Wiring Diagram.
- Continue
OKAY: Troubleshooting has been completed.