Checking Cables
Check the control module and the damper motor connectors for contact resistance and oxidation according to Contact Resistance And Oxidation .
Check the signal cable between the MCC control module #B3 and the damper motor terminal 3 for an open-circuit according to Open-Circuit, Permanent Faults , and a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
Check the ground lead between the MCC control module #B1 and the damper motor terminal 1 for an open-circuit according to Open-Circuit, Permanent Faults .
Check the cable for power supply between the MCC control module #B2 and the damper motor terminal 2 for a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
If the cables are OK, try a new recirculation damper motor.
Remedy as necessary.
Other information:
- To disconnect the control module, see Replacing Or Adjusting Control Cables/Mechanical Rear Section And Control Panel/Front Section (Manual Climate Control/STANDARD) .
- To access/replace recirculation damper motor, see Replacing Damper Motor Recirculation
- To connect the breakout box, see Connection Of Breakout Box MCC .
- Voltage on signal cable varies between approximately 0-5 V depending on damper motor position. Damper motor power supply should be approximately 5 V. For other values, see Signal Descriptions MCC .
- Continue