Checking Cables
Check the ECC control module and combined instrument panel connectors for contact resistance and oxidation according to Contact Resistance And Oxidation .
Check signal cable between ECC control module #B1 and combined instrument panel # A6 for an open-circuit according to Open-Circuit, Permanent Faults , a short-circuit to ground according to Short-Circuit To Ground, Permanent Faults and a short-circuit to supply voltage according to Short-Circuit To Supply Voltage. Permanent Faults .
Corrective action as necessary.
Other information.
To connect the breakout box, see Connection Of Breakout Box ECC .
To access the combined instrument panel, refer to Replacing the Combined Instrument Panel .
To remove the control module, refer to Replacing ECC Control Module .
- Continue
Refer to Verification