Home >> Volvo >> 2003 >> C70 2.3 53, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 75 (Climate Units - Cleaning, Inspection And Adjustment (Coupe)) >> Climate Control System, General (1998-2002) >> Oil Air Conditioning (A/C) System, Filling >> Topping Up the Lubricating Oil >> Notes

Topping Up the Lubricating Oil: Notes

WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Do not  mix oil types. Always use the correct type of compressor oil.
NOTE: Too much lubrication oil will impair cooling. Too little lubrication oil will damage the compressor.

The oil must be topped up when repairing a leak or when replacing a component. The quantity required for the component in question will depend on whether leakage has taken place slowly or quickly.

Slow leakage (longer than 24 hours) 

With a slow leak, there is normally minimal risk of oil loss.

When installing new components the following procedures apply:

When replacing components, the following oil volumes shall be found in the new components or shall be filled in the system through the service valve, except for the compressor (see the section "Compressor" below):

Accumulator 90 cm3
Evaporator 40 cm3
Condenser 30 cm3
Tube 10 cm3
Hose 10 cm3

Compressor 

Oil return when reusing compressor: 

Drained oil  Filling with oil 
≥ 70 cm3 oil Replace the volume of drained oil with the corresponding quantity.
< 70 cm3 oil Fill with 70 cm3 of oil.

Oil return when replacing compressor: 

Drained oil  Filling with oil 
≥ 70 cm3 oil Replace the drained oil volume with the same amount that was drained from the old compressor.
< 70 cm3 oil Fill with 70 cm3 of oil.
CAUTION: When installing completely new system: Check that there is oil in the compressor. The other components should contain no oil.

Rapid leakage (hose rupture) 

Rapid leakage often means that lubricating oil escapes with the refrigerant.

If the hose has ruptured, add 200 cm 3 .