Checking cable
WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition off.
Disconnect VGLA control module connector A.
Connect an ohmmeter between contact reel #A10 and ground, measure for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Remedy as necessary.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm (VGLA) .
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) .
- To access the control module connector, see Replacing the control module .
- To access the SRS control module connector, see SRS control module .
Was a fault found?
- YES
Refer to Verification
- NO
FAULT NOT FOUND: Troubleshooting has been completed.