Checking for open-circuit
Check circuit between fuse number 11C/4 and battery positive terminal for an open-circuit according to Open-circuit, permanent faults
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check cable between fuse 11C/4 and control module terminal #5 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check the circuit between battery positive terminal and fuse 11C/8 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check cable between fuse 11C/8 and control module terminal #6 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check the cable between control module terminal #8 and ground terminals 31/51 and ground terminal itself for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification