Checking ground to Volvo Scan Tool (ST)
- Ignition off.
- Cabling to Volvo Scan Tool (ST) connected to the data link connector (DLC).
- 3-pin connector disconnected from Volvo Scan Tool (ST).
Connect an ohmmeter between the 3-pin connector terminal 2 (to the data link connector (DLC)) and ground.
The ohmmeter should read 0 Ω.
- OK
Refer to Checking display activation
- NOT OK
Refer to Try a new adapter box