Checking ground terminals
- Ignition off.
- Switch off all equipment that takes power from the battery (courtesy lighting, radio etc).
Connect an ohmmeter between the battery negative terminal and
#15 (#A15)
#17 (#A17) on the breakout box.
The ohmmeter should read approximately 0Ω for all readings
- OK
FAULT NOT FOUND: Troubleshooting has been completed.
- NOT OK
Refer to Checking for an open-circuit