LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Transmission >> Manual Trans >> Transmission - Removal, Replacement And Installation - 2 Of 2 >> Transmission, Automatic (B5204T5, Aw55-50/51SN; 2004-2007) >> Solenoid Control System, Replacing >> Replacing And Checking Solenoids >> Checking the resistance of SLT, SLS and SLU

Checking the resistance of SLT, SLS and SLU

Fig 1: Identifying S1-S5 Solenoids
GLL109420Courtesy of VOLVO CARS OF NORTH AMERICA.
NOTE:

Readings should be taken at approximately 20°C.

Solenoid SLT, SLS and SLU 

Measure the resistance between both the pins in the solenoid connector.

Correct value: 5.0-5.6 Ω.

If the value of any of solenoids SLT, SLS and SLU is incorrect 

Replace the control system. See Replacing the control system .

The control system is calibrated together with the solenoids.