LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Transmission >> Manual Trans >> Transmission - Removal, Replacement And Installation - 2 Of 2 >> Transmission, Automatic (B5204T5, Aw55-50/51SN; 2004-2007) >> Solenoid Control System, Replacing >> Replacing And Checking Solenoids >> Check the resistance in S1-S5

Check the resistance in S1-S5

Fig 1: Identifying S1-S5 Solenoids
GLL109420Courtesy of VOLVO CARS OF NORTH AMERICA.
NOTE:

Readings should be taken at approximately 20°C.

Solenoid S1 

Measure the resistance between the pin in the solenoid connector and the transmission ground terminal.

Correct value: 12-16 Ω.

Solenoids S2-S5 

Measure the resistance between the pin in the solenoid connector and the transmission ground terminal.

Correct value: 11-15 Ω.

If the resistance of any of solenoids S1-S5 is incorrect 

Replace the solenoid. See Replacing solenoids S1-S5 .