Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Steering >> Power Steering >> Electrical & Accessory Systems - Symptom Related Diagnostic Procedures >> Checking The Lock Function Of The Trunk Lid (2001-2004) >> Checking the lock function of the trunk lid >> Checking for a short-circuit

Checking for a short-circuit

Measure the resistance between the fuse holder secondary side (left) and ground.

The ohmmeter should read infinite resistance.

If the value is correct, replace the fuse.

NOTE:

The fault could be intermittent.

If the value is incorrect, fault-trace all affected relay circuits and component wiring for a short-circuit to ground.

HINT: Replace fuse. 

HINT: If the fuse blows immediately the short-circuit is in the relay power cable. 

HINT: If the fuse blows when the tailgate is opened the short-circuit is in the power supply cable for the component 

HINT: Relay supply cable: fuse 11D/6 terminal #5 relay base 2/67. 

HINT: Component supply cable: terminal #4 relay base 2/67 terminal #2 lock unit. 

Other information 

Fig 1: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relays And Terminals
GLL104090Courtesy of VOLVO CARS OF NORTH AMERICA.