LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Steering >> Power Steering >> Electrical & Accessory Systems - Symptom Related Diagnostic Procedures >> Checking The Lock Function Of The Fuel Tank Filler Cover (2001-2004) >> Checking the lock function of the fuel tank filler cover >> Checking for a short-circuit

Checking for a short-circuit

Measure the resistance between the fuse holder secondary side (left) and ground.

The ohmmeter should read infinite resistance.

If the value is correct, replace the fuse.

NOTE:

The fault could be intermittent.

Fault-trace all affected relay circuits for a short-circuit to ground if the value is incorrect.

HINT: Replace fuse. 

HINT: If the fuse blows immediately the short-circuit is in the relay power cable. 

HINT: If the fuse blows when the relevant relay is activated, the short-circuit is in the component power supply cable 

HINT: The relay circuits affected are from relays 2/111, 2/112, 2/113, 2/114, 2/115, 2/56, 2/59 and 2/67. 

Other information 

Fig 1: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relays And Terminals
GLL104090Courtesy of VOLVO CARS OF NORTH AMERICA.