Short-circuit to ground, intermittent faults
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2006 Volvo S80, 2005 Volvo S80, 2004 Volvo S80, 2003 Volvo S80, and 2002 Volvo S80. However, it is still accessible from the selected car via links, so may be relevant.
A short-circuit between a live cable and ground is often indicated by the loss of a function or a fuse blowing when a current is passed through the cable.
Checks:
- Check the cables visually according to Inspect terminals visually .
Activate all switches and sensors in the circuit. Check whether the fuse blows
- Disconnect the connectors in the circuit to ensure that they do not affect readings.
Connect an ohmmeter between cable and ground.
The ohmmeter should read infinite resistance if no components are connected.
Shake the cable lightly and pull on connectors during measurement to locate the damage.
If the reading is not correct, replace the cable and / or continue according to Contact resistance and oxidation .