LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Engine Performance >> Tune-Up >> Ignition And Control Systems - Specifications, Other >> DENSO Plotter Parameters (B5244S; 2001-2002) >> Description Of Parameters, Denso >> Parameters, Value >> Front Heated Oxygen Sensor (HO2S), Power Consumption Heater Pad (A)

Front Heated Oxygen Sensor (HO2S), Power Consumption Heater Pad (A)

Probe heating in the front heated oxygen sensor (HO2S).

Measurement range -63 - +3163 mA.

Actual electrical consumption required to maintain the correct probe temperature.