Checking the wiring
Check the power supply cable between control module terminal #A39 (#A39) and mass air flow (MAF) sensor terminal #4. Check for a short-circuit to ground.
Check the power supply cable between control module terminal #A39 (#A39) and boost pressure sensor terminal #3. Check for a short-circuit to ground.
Check the power supply cable between control module terminal #A39 (#A39) and air conditioning (A/C) pressure sensor terminal #3. Check for a short-circuit to ground.
HINT: Read off the voltage of the 5-volt power supply by clicking on the VCT2000 symbol.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- For information about signals on 5 cylinder engines, see Signal specification
- For the location of components on 5 cylinder engines, see Location of components
- To access or replace the boost pressure sensor, see Temperature and pressure sensor, replacing
- See Contents .
- Continue
Refer to Verification