LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Control Module (ECM) - Diagnostic Trouble Codes And Associated Procedures - 9 Of 14 >> ECM-6410: Camshaft Reset Valve, Exhaust. Signal Missing (B5244S; B5244S6; 2005-2006) >> Signal Missing >> Checking Wiring And Terminals

Checking Wiring And Terminals

HINT: With the ignition on and the reset valve connector disconnected, the voltage at connector terminal #1 must be approximately Ubat and at connector terminal #2 it must be a pulse width modulated signal with a peak voltage of approximately Ubat and with a frequency of approximately 250 Hz. 

Check the resistance between connector terminals #1 and #2 on the camshaft reset valve. The resistance must be approximately 3.7 Ω.

Check the signal cable between engine control module (ECM) terminal #A12 (#A12) and connector terminal #2 (on the camshaft reset valve). Check for an open-circuit.

Remedy as necessary.

Other information 

Fig 1: Identifying Camshaft Reset Valve Connector Terminals
GLL104010Courtesy of VOLVO CARS OF NORTH AMERICA.