Checking The Wiring
Check the fuse before the circuit. If the fuse is blown, check the circuit for a short-circuit to ground.
Check the power cable between the fuse of the circuit and terminal #1 of the control module cooling fan for open circuit.
Check the signal cable with regard to open circuit.
Take readings between:
- Engine Control Module (ECM) terminal #B48 (#B58) and terminal #2 of control module cooling fan.
If no faults are found via the aforementioned fault tracing, replace the control module cooling fan.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- See Contents .
- Continue
Refer to Information