Checking the wiring
Check the signal cable between engine control module (ECM) terminal #A40 and oil level sensor terminal #1. Check for a short-circuit to ground.
HINT: With the ignition on, the voltage between terminals #2 and #3 must be 5 V, with the reading taken at the oil level sensor connector.
Try a new oil level sensor if no fault is found and the fault is permanent.
Remedy as necessary.
Other information:
- See Contents
- To connect the breakout box, see Connecting the breakout box
- For information about signals, see Signal specification
- To access or replace the oil level sensor see Oil level sensor, replacing .
- Continue