Checking components and wiring
Check the signal cable between control module terminal #A23 (#A23) and boost pressure sensor terminal 1. Check for an open-circuit. Check for a short-circuit to supply voltage.
HINT: With the ignition on and the boost pressure sensor connector disconnected, the voltage between terminal 1 and ground terminal must be approximately 5 V.
Check the ground lead between control module terminal #A60 (#A60) and boost pressure sensor terminal 2. Check for an open-circuit.
Remedy as necessary.
Other information
- To connect the breakout box / access the control module, see connecting the breakout box
- To access or replace the boost pressure sensor, see Temperature and pressure sensor, replacing
- For information about signals, see ELECTRICAL SYSTEM
- See Contents .
- Continue
Refer to Verification