Connect the test pressurization equipment
Courtesy of VOLVO CARS OF NORTH AMERICA.
Remove:
- the hose clamp (2) between the mass air flow (MAF) sensor and the intake manifold for the turbocharger (TC)
- the screws for the intake manifold. Fold the pipe up. Connect tool
9995545
and pressure regulator
9995544
to the intake manifold. Tighten the hose clamp.