Checking the Power Supply
Check interior fuse 24 (11C/24:2).
Check the wire between combined instrument power supply relay (2/29) 3 and interior fuse 24 (11C/24:2) for an open circuit as described in Open-Circuit, Intermittent Faults , and for a short circuit to ground as described in Short-Circuit To Ground, Intermittent Faults .
Check that the relay is not defective.
Check and measure wire between combined instrument 6 and handbrake contact 1 for a short circuit to ground as described in Short-Circuit To Ground, Intermittent Faults .
Check the wire between combined instrument 1 and combined instrument power supply relay (2/29) 1 for an open circuit as described in Open-Circuit, Intermittent Faults , and a short circuit to ground as described in Short-Circuit To Ground, Intermittent Faults .
Check the wire between combined instrument 14 and ground for an open circuit as described in Open-Circuit, Intermittent Faults , and for a short circuit to voltage supply as described in Short-Circuit To Supply Voltage, Intermittent Faults .
Do the necessary corrective action.
Additional information:
- To connect the test box, see Connecting the Driver Information Module (DIM) Test Box .
- Continue
Refer to Checking the Ground Terminals