Additional functions of the Volvo Battery Analyser 3100/3200
Test code
The INFORMATION (i) button (see the instruction card) can be pressed at any time when reading off the test results or state of charge to read off the test code. Press INFORMATION again to return to test results or state of charge. The test code is used when making warranty claims.
| TEST CODE XXXX XXXX |
||
The test code is only accessible when testing genuine VOLVO batteries.
If the INFORMATION button is pressed after testing a battery other than a VOLVO original battery, the following message is displayed:
| NON-VOLVO BATTERY TEST |
||
Charging code
The ENTER button (see the instruction card) can be pressed at any time when reading off test results or the state of charge to obtain the charging code. Press ENTER again to return to the test results or state of charge.
| CHARGE CODE XX |
||
This function is not used at present.
Eliminating surface charging
When testing in the car is selected and the tester detects surface charge, a message will be displayed requesting that the headlamps are switched on to remove the surface charge. For an explanation of surface charging, see Surface charging .
| 1/ SURFACE CHARGE DETECTED |
||
| 2/ TURN KEY ON HEADLAMPS ON |
||
| 3/ LOAD ON DETECTED |
||
| 4/ TURN KEY OFF HEADLAMPS OFF |
||
| 5/ LOAD OFF DETECTED |
||
After the tester has detected that the surface charge has gone, it will automatically carry out the test and display the results as described previously.
| ** RETESTING ** 500 A (SAE) |
||
| ** RETESTING ** 500 A (DIN) |
||
If the surface charge is not removed correctly, a warning window will be displayed, followed by a message. These two windows will be displayed for 3 seconds each, followed by an appropriate remedy as in windows 2 and 4 above.
| *** WARNING *** . |
||
| LOAD ON NOT DETECTED |
||
| LOAD OFF NOT DETECTED |
||
If this sequence is repeated for more than 30 seconds, the following window will be displayed. The tester must then be disconnected from the battery, reconnected and the test started from the beginning again.
| DISCONNECT AND RETEST |
||
Testing before or after charging
To obtain a more exact test result, the tester will ask if it is testing before or after charging. Select the correct alternative. Then press the ENTER button (see the instruction card).
| SELECT MODE ↑↓ BEFORE CHARGE ← |
||
| SELECT MODE ↑↓ AFTER CHARGE ← |
||
Detecting system noise
If the tester detects system noise from the control modules, ignition system or another consumer the following message will be displayed. Switch off as many power consuming components as possible. The tester will retest automatically.
| SYSTEM NOISE CHECK LOADS |
||
| ** RETESTING ** 500 A (SAE) |
||
| ** RETESTING ** 500 A (DIN) |
||
Temperature compensation
If the tester determines that the battery temperature may affect the test result, the following message is displayed. Check the temperature of the battery. Then select above or below 0◦C (32◦F). Then press ENTER (see the instruction card) to continue the test.
In cold conditions, measure the temperature of the battery container.
| BATTERY TEMP. ↑↓ ABOVE 0°C ← |
||
| BATTERY TEMP. ↑↓ BELOW 0°C ← |
||
The retest window will be displayed and then the test result.
| ** RETESTING ** 500 A (SAE) |
||
| ** RETESTING ** 500 A (DIN) |
||
Protection against 24-volt systems
If for any reason an attempt is made to test a battery other than a 12 volt battery, or if an attempt is made to test both the 12 volt batteries in a 24-volt system at the same time, the following warning window will be displayed:
| NON 12 VOLT BATTERY DETECTED |
||
Message to check the connections
If a good connection to the battery is not obtained, the following message will be displayed. If this is the case, check the connections by working the cable terminals on the test tool forwards and backwards.
| CHECK CONNECTION . |
||