Intermittent fault
Check the control module and power window lift motor connectors. Check for contact resistance and oxidation. See Contact resistance and oxidation . Check for loose connections. See Loose connections (terminals) .
Check the cable between control module terminal #23A and power window lift motor terminal #2. Check the cable between control module terminal #24A and power window lift motor terminal #5. Check for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults . Check for an intermittent short-circuit to supply voltage according to Short-circuit to supply voltage, intermittent faults . Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
Check the cable between door control module terminal #16A and power window lift motor connector terminal #4. Check for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults . Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
Check the cable between door control module terminal #19A and power window lift motor connector terminal #1 for an intermittent open-circuit according to Open-circuit, intermittent faults .
Other information:
- To connect the breakout box, see Connecting the breakout box
- For further information about signals and other values, see Signal specification .
- Continue
Refer to Information