Checking components and wiring
Check signal cable M1 between door control module connector terminal #B2 and central locking motor connector terminal #8. Check for a short-circuit to supply voltage.
Check signal cable M2 between door control module connector terminal #B62 and central locking motor connector terminal #7. Check for a short-circuit to supply voltage.
Check signal cable M3 between door control module connector terminal #B1 and central locking motor connector terminal #6. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To fault-trace wiring and terminals see Checking wiring and terminals
- To connect the breakout box, see Connecting the breakout box
- To access and replace the door control module, see Driver's door module / passenger door module (DDM/PDM), replacing
- For information about signals, see Signal specification .
- Continue
Refer to Verification