Checking the canister purge (CP) valve
- Canister purge (CP) valve connector disconnected
- Ignition on.
Connect an ohmmeter between canister purge (CP) valve connector terminals #1 and #2.
The ohmmeter should read approximately 21 Ω at +20 °C.
- OK
Refer to Checking the power supply
- NOT OK
Refer to Defective canister purge (CP) valve