Intermittent fault
Check the control module and TMC/FM receiver connectors for contact resistance and oxidation according to Contact resistance and oxidation .
Check signal cable between the control module #B7 and TMC/FM receiver terminal 2 for an intermittent open-circuit according to Open-circuit, intermittent faults and an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
Check signal cable between the control module #B16 and TMC/FM receiver terminal 3 for an intermittent open-circuit according to Open-circuit, intermittent faults and an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults , and an intermittent short-circuit to supply voltage according to Short-circuit to supply voltage, intermittent faults .
Remedy as necessary.
Other information:
- To access/replace the control module, see Replacing the control module, old system .
- To access/replace the TMC receiver, see Replacing TMC receiver .
- To access/replace the FM receiver, see Replacing the FM receiver .
- To connect the breakout box, see Connecting the breakout box .
- Continue
Refer to Information