Home >> Volvo >> 1998 >> S70 Base, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Diagnostic Tests >> DTC P0300/EFI 543-EFI 545, DTC P0301/EFI 451-EFI 551, DTC P0302/EFI 452-EFI 552, DTC P0303/EFI 453-EFI 553, DTC P0304/EFI 454-EFI 554 & DTC P0305/EFI 455-EFI 555 >> Fault Conditions (DTC EFI-45x, EFI-543

Fault Conditions (DTC EFI-45x, EFI-543

If the ECM registers more than 0.5% misfires in 1.000 engine revolutions (2500 ignition sequences), the ECM checks whether this misfiring comes from one specific cylinder or from different cylinders. If only one cylinder exceeds the limit, DTC EFI-543 is stored first and then one of DTCs EFI-451, EFI-452, EFI-453, EFI-454 or EFI-455, depending on the cylinder. If more than one cylinder exceeds the limit DTC EFI-543 is stored with a DTC for the relevant cylinder.