Checking the 30-supply
Check that the function switch opens and closes between #2 (ground) and #3, #4 respectively #5 in the correct way.
Replace the function switch if necessary.
Check the signal cables between the function switch and the combined instrument panel for an open-circuit according to Open-circuit, permanent faults , a short-circuit to supply voltage according to Short-circuit to ground, permanent faults , and a short-circuit to ground according to Short-circuit to supply voltage. Permanent faults .
Check that all six trip computer functions can be selected using the function switch.
HINT: The voltage between signal cables and ground should be 5 V with the function switch disconnected.
Other information:
- For information about signals, see Connector D, #D1-#D5 .
- To connect the breakout box, see Connecting breakout box, Combined instrument panel .
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO
FAULT NOT FOUND: Troubleshooting has been completed.