Checking power supply
Check that the battery charges normally when the motor is running/generator (GEN) charging.
Check display connector for contact resistance and oxidation according to Contact resistance and oxidation .
Check the cables between the display #11 and #12 and fuses 15 and 30 for an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Other information:
- To access/replace the display, see Replacing the display .
Were any faults found?
- YES
OKAY: Troubleshooting has been completed.
- NO
FAULT NOT FOUND: Troubleshooting has been completed.