LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 1985 >> 245 GLT, Automatic, AW71 >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel - Standard >> Testing >> Temperature & Fuel Gauge >> Gauges (760 GLE)

Gauges (760 GLE)

  1. Disconnect lead at sensor. Connect 68 ohm Resistor (999 5824-1) between ground and disconnected lead. If a 75% deflection is obtained, gauge is okay but sensor is defective.