Gauges (760 GLE)
- Disconnect lead at sensor. Connect 68 ohm Resistor (999 5824-1) between ground and disconnected lead. If a 75% deflection is obtained, gauge is okay but sensor is defective.
- For all other readings, gauge or voltage regulator is defective. If problem is with voltage regulator, both gauges will not work.