Battery, Charging
If software updates or flash campaigns/actions must be performed on a vehicle, a charger with at least 70A (for example Battery Charger "VAS5903") must be used in order to avoid problems during software updates and flash campaigns/actions. Refer to Battery Charger .
Requirements:
Batteries that have a light yellow visual indicator do not have to be tested or charged. Do not give a jump start.
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
Battery Tester Charger Kit GRX3000VAS output - setup performed (unit number, date/ time). Refer to Battery Tester Charger Kit GRX3000VAS Operating Instructions.
-- General information, checking. Refer to Battery Tester Charger Kit .
-- Open the hood or open the cover if the battery is installed somewhere else.
-- Visually inspect the battery. Refer to VISUAL INSPECTION .
-- Determine if it is a "standard" battery (wet battery) or an "AGM" battery.
-- Close all vehicle doors.
The battery temperature must be at least 10 °C (50 °F).
Refer to the Battery Tester Charger Kit GRX3000VAS Operating Instructions for more information.
Perform the Charging Procedure:
-- Switch off all electrical equipment.
-- Turn off the ignition and remove the ignition key.
-- Clamp the red charging clamp "+" of the charger to the positive battery terminal.
In the case of vehicles with a start/stop function and an installed Battery Monitoring Control Module: J367 , the black charging clamp - must be connected to the body ground. The start/stop system will malfunction if it is connected to the negative terminal on the battery.
-- Connect the black charging clamp "-" of the charger to the negative battery terminal.
-- Connect the Battery Tester Charger Kit: GRX3000VAS battery charger to a grounded socket.
-- Switch the "ON/OFF" switch on the Battery Tester Charger Kit: GRX3000VAS battery charger to "ON".
-- Select the charge mode "automatic" or "manual.".
-- Select the test: "inside the vehicle" or "outside of the vehicle".
-- Determine if it is a "standard" battery or an "AGM" battery.
-- Select the type of test: "Warranty" or "other". Note any other additional details (depending on the type of test).
Refer to the Battery Tester Charger Kit GRX3000VAS Operating Instructions for more information.
If necessary, go through all the menu points when performing a "Warranty" test. Refer to Warranty Service Circulars.
The Battery Tester Charger Kit: GRX3000VAS battery charger checks the battery and starts the charging process. The display then show one of three results with the exact charging time.
| Result: | Measure: |
|---|---|
| Battery good | The battery can be used again. |
| Charging is required |
|
| Replace the battery | Battery faulty. The charging process is interrupted. Replace the battery. |
If other malfunction messages or text displays, other than the ones already mentioned, appear in the display on the Battery Tester Charger Kit: GRX3000VAS battery charger, refer to chapter Battery Tester Charger Kit .
If the battery starts to vent gas heavily, stop the charging process. Press the "Stop" button on the front side.
After the charging and testing process is completed, the Battery Tester Charger Kit: GRX3000VAS battery charger will display "battery good" or "replace the battery" and the total charging time.
Depending on the individual circumstance (Warranty Claim, Repair Order, Evaluation and File), there are three possible messages:
- Produce a test code (possible only after automatic charging and testing).
- Print last test result (for Warranty)
- Display the last test result.
Refer to the Battery Tester Charger Kit GRX3000VAS Operating Instructions for more information.