Refrigerant Shut-Off Valve 2 -N640-, Removing And Installing: Removing

The Refrigerant Shut-Off Valve 2 -N640- and Refrigerant Shut-Off Valve 3 -N641- cannot be replaced separately.

 

-- Remove the heat pump valve unit. Refer to Heat Pump Valve Unit, Removing and Installing  .

 
CAUTION:

Risk of damaging electrical components.

The electrostatic charge can damage electrical components.

- Procedures at the electrical components must only be performed at an electro-static discharge work surface.

-- Place the heat pump valve unit on the ESD Work Surface:VAS 6613  .

 

-- Insert the Counterholder:T10630  -4-.

GWWN87-12464Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Remove the bolts -1-, -2-, -3- and -5-.

-- Remove the refrigerant lines.

 

-- Mark the connectors -2- due to risk of interchanging, then disconnect.

GWWN87-12277Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Remove the bolts -3-.

-- Remove the Refrigerant Shut-Off Valve 2 -N640- and the Refrigerant Shut-Off Valve 3 -N641- -1-.