Refrigerant Expansion Valve 1 -N636-, Removing And Installing: Removing
The Refrigerant Expansion Valve 1 -N636- and Refrigerant Shut-Off Valve 1 -N696- cannot be replaced separately.
-- Remove the heat pump valve unit. Refer to Heat Pump Valve Unit, Removing and Installing .
CAUTION:
Risk of damaging electrical components.
The electrostatic charge can damage electrical components.
- Procedures at the electrical components must only be performed at an electro-static discharge work surface.
-- Place the heat pump valve unit on the ESD Work Surface:VAS 6613 .
-- Remove the bolts -1-, -2- and -3-.
-- Mark the connectors -2- due to risk of interchanging, then disconnect.
-- Remove the bolts -3-.
-- Remove the Refrigerant Expansion Valve 1 -N636- and the Refrigerant Shut-Off Valve 1 -N696- -1-.