Refrigerant Gas Analysis, Performing
- The gas analysis is used to meet the specified purity of the refrigerant, to detect contaminated refrigerants and to protect the A/C Service Station.
- Without a gas analysis no refrigerant should be removed from the A/C Service Station.
- Use of the wrong refrigerant will void the operating permit for the vehicle.
-- Connect the Gas Analyzer or A/C Service Station to the refrigerant circuit according to the owner's manual and start up. Refer to Owner's Manual.
-- Perform the gas analysis according to the owner's manual. Refer to Owner's Manual.
TIP
- A minimum refrigerant circuit pressure is necessary (for example 2.5 bar at an ambient temperature of 20 °C (68 °F)) for performing the gas analysis.
- If no sufficient pressure can be built up due to very little refrigerant left in the circuit, then it might not be possible anymore to perform a gas analysis, depending on the version of the A/C Service Station or the Gas Analyzer. Refer to Owner's Manual.
The following values apply for a gas analysis of clean refrigerant R1234yf:
- The extracted refrigerant gas is made up of a minimum of 95 % refrigerant R1234yf.
- The portion of foreign gases (oxygen, nitrogen, steam, and other refrigerants) is smaller than 5 %.
Refrigerant does match the specifications.
-- Perform the necessary procedures using the A/C Service Station. Refer to WORKING WITH A/C SERVICE STATION .
Refrigerant does not match the specifications:
-- Return the contaminated refrigerant to, for example, the gas supplier for analysis, processing or disposal. Refer to CONTAMINATED REFRIGERANT, FILLING IN RECYCLING CYLINDER FOR ANALYSIS, PROCESSING, OR DISPOSAL .
If the gas analysis determines contaminated refrigerant or refrigerant of unknown composition, then the client must be made aware of this situation before continuing the procedures.
- If the wrong refrigerant has been used in the refrigerant circuit, then a special evaluation must be performed and appropriate measures must be taken.