Overview - Evaporator Housing
There are different versions and manufacturers of the heater and A/C units. Individual components of the different heater and A/C units are similar but not the same. Interchanging components from different manufacturers is not permitted. Refer to the Parts Information.
A "Valeo" evaporator housing is shown in the following illustration. Refer to IDENTIFICATION for the different manufacturers' distinguishing characteristics of the heater and A/C units.
For A/C systems with refrigerant R1234yf, the desiccant bag/dryer cartridge must be replaced each time the refrigerant circuit is opened. Refer to COMPONENTS, REPLACING .
Under certain conditions, the desiccant bag no longer needs to be replaced each time the refrigerant circuit is opened on A/C systems with refrigerant R134a. Refer to COMPONENTS, REPLACING .
The image shows a LHD.
- Seal/Insulation
- Expansion valve heat insulation
- Seal/Insulation
- Expansion valve heat insulation
- Bolt
- Quantity: 2
- 10 Nm
- Expansion Valve
- Removing and Installing. Refer to EXPANSION VALVE, REMOVING AND INSTALLING .
- Retaining Plate
- Only with A/C system
- For securing the refrigerant line and fastening the expansion valve
- Evaporator Housing Upper Section
- Bolts
- 1.5 Nm
- Evaporator
- Check the foam seals for damage and that they are correctly bonded
- Removing and Installing. Refer to EVAPORATOR, REMOVING AND INSTALLING .
- Evaporator Housing Lower Section